开发和验证一个高度敏感的评价利培酮分光光度法测定纯和剂型
作者(年代):Hemavathi N。Deepakumari, Hosakere D.Revanasiddappa紫外光谱分析方法广泛适用于测定化合物的常规分析方法。本文描述了一个简单的,高度敏感的评估和验证紫外-分光光度法测定利培酮(负责)在纯和制剂。该方法是基于测量吸光度的负责在四氢呋喃,显示最大吸光度在285海里。校准曲线是线性浓度范围的5 ig / 0.5毫升与相关系数(r) 0.9994。表观摩尔吸光系数为6.497×104 l / mol /厘米。方法给了令人满意的结果的可重复性、中间精密度(RSD < 3.0%)。Themethod开发验证和证明是健壮的,崎岖的。结果表明,该方法成功地应用到利培酮在平板电脑市场的决心,和结果统计和文献方法相比,采用StudentAs t检验和F -测试。紫外光谱分析方法广泛适用于测定化合物的常规分析方法。本文描述了一个简单的,高度敏感的评估和验证紫外-分光光度法测定利培酮(负责)在纯和制剂。该方法是基于测量吸光度的负责在四氢呋喃,显示最大吸光度在285海里。 Calibration graph is linear in the concentration range of 0.5 Â 5 ìg/ml with correlation coefficient (r) 0.9994. The apparent molar absorptivity is 6.497 × 104 l/mol/cm. The method gave satisfactory results in terms of repeatability and intermediate precision (RSD< 3.0%). Themethod developed was validated and proved to be robust and rugged. The results showed that this method was successfully applied to the determination of risperidone in tablets, and the results were statistically compared with those of the literature method by employing StudentÂs t-test and F- test.